PRODUCT SERVICE MANUAL
FOR
CIG Mechanical Seal Single Pumps
WARNING
The Imo General Installation Operation, Maintenance, and Troubleshooting
Manual, (No. SRM00046), as well as all other component manuals supplied
with these type units should be read thoroughly prior to pump installation,
start-up, operation, maintenance or troubleshooting.
SRM00050 REV. 03 (14-0132 MARCH 2014
Page view 0
1 2 3 4 5 6 ... 16 17

Summary of Contents

Page 1 - PRODUCT SERVICE MANUAL

PRODUCT SERVICE MANUAL FOR CIG Mechanical Seal Single Pumps WARNING The Imo General Installation Operation, Maintenance, and Troubles

Page 2 - CONTENTS

8 K. REASSEMBLY OF PUMP CAUTION ATTENTION READ THIS ENTIRE PROCEDURE BEFORE ASSEMBLING PUMP NOTE: Inspect all running surfaces for scratching,

Page 3

9 CAUTION ATTENTION Take extreme care not to damage seal mating face or O-ring during assembly. Do not touch seal face with any tools. After inst

Page 4

10 17. Reinstall bearing retainer (70) onto bearing housing (9) with cap screws (75). Tighten capscrews with torque wrench per assembly drawing torqu

Page 5

11 27. Install second stage pinion gear (11) on shaft (6). Pinion gear (11) should slide freely on shaft (6) and key (13). If not, ensure key (13) is

Page 6

12 CAUTION ATTENTION If gears are installed in wrong housing, pump may not perform properly or may seize during operation. This is because gears a

Page 7

"X2" TORQUE TABLE FRAME SIZE BOLT SIZE PUMP MODIFICATION TORQUE LB FT N.m 2 M10 w 30 ±2 41 p 3 M12 w 60 ±5 81 p 4 M16 w 115 ±10

Page 8 - I. MACHINING INSTRUCTIONS

"X1 and "X2" "X3" "X4" "X5 and "X6" Frame Size Bolt Size Pum Mod Torque Torque Torque Torque lb-ft

Page 9

Imo Pump 1710 Airport Road PO Box 5020 Monroe, NC USA 28111.5020 Tel: +1.704.289.6511 Toll: +1.877.853.7867 Email: [email protected] Web:c

Page 10

READ THIS ENTIRE PAGE BEFORE PROCEEDING FOR THE SAFETY OF PERSONNEL AND TO PREVENT DAMAGE TO THE EQUIPMENT, THE FOLLOWING NOMENCLATURE HAS BEEN US

Page 11

1 A. GENERAL INSTRUCTIONS The instructions found herein cover the disassembly, assembly and parts identification of CIG single mechani

Page 12

2 4. From the assembly drawing or instruction manual (see Table 1, Pump Parts List) provide the IDP number(s) and names for the replacement part(s).

Page 13

3 4. Remove square housing (4), ring gear (12), pinion gear (11) and key (13) from shaft (6). Do not permit dowel pin (37) to drop as housing (

Page 14

4 NOTE: If round gear housing (3) will not slide easily off shaft (6) and this is the last round housing (3) to be removed, clamp round housing (3)

Page 15 - "X2" TORQUE

5 15. Remove O-rings (40 and 80) from bearing housing (9). NOTE: If neither ball bearing (31) nor seal (51) are to be replaced or inspected, disass

Page 16 - & 5

6 3. RING GEAR OD – Light scratching and polishing is acceptable. If scoring is present, ring gear should be replaced. 4. HOUSING a. Faces – So

Page 17

7 Figure 2 – Front Cover Figure 3 – Sleeve Bearing (53) Sizing Tool J. SPARE PARTS AND KITS IDP Qty. Description Seal Kit Shaf

Comments to this Manuals